Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
HSS800T01800 Amps rated open loop Hall ef ELECTROHMS |
107 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 800A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HJ050T0250 Amps rated Split core Hall ef ELECTROHMS |
102 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 50A | 1 | Analog Voltage | - | DC ~ 20kHz | ±1% | ±2% | 5V | - | 18mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HE300T04300 Amps rated closed loop Hall ELECTROHMS |
1,800 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HE200T04200 Amps rated closed loop Hall ELECTROHMS |
435 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 200A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HSM2K5T012500 Amps rated open loop Hall e ELECTROHMS |
50 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 2500A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HSM2K0T012000 Amps rated open loop Hall e ELECTROHMS |
30 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 2000A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HE500T02500 A rated closed loop Hall eff ELECTROHMS |
100 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Current | 0.2mA/A | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HED1K0T011000 Amps rated ,closed loop Hal ELECTROHMS |
100 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 1000A | 1 | Current | 0.2mA/A | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
VJ1K5T03Voltage sensors 1500 Vrms rating ELECTROHMS |
100 |
|
![]() |
- | Module | Bulk | Active | AC/DC | Current Sensor | - | 1 | Current | - | DC ~ 14kHz | ±1% | ±1% | 13.5V ~ 26.4V | 60µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HS500T01500 Amps rated open loop Hall ef ELECTROHMS |
100 |
|
![]() |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |